All alternatives

View full report

Technical parameters

Power
Lowest operating currentI m | 2 mA
Off-state currentI r | ≤ 200 µA
Operating currentI L | 2 ... 30 mA
Operating voltageU B | 4 ... 30 V
Voltage dropU d | ≤ 4 V
AC and DC characteristics
Switching frequencyf | 0 ... 500 Hz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Other
Actual operating distances r | 7.2 ... 8.8 mm
Assured operating distances a | 0 ... 6.48 mm
Bending radius> 10 x cable diameter
Cable diameter4.8 mm ± 0.2 mm
Colorgrey
Connection typecable
Core cross section0.34 mm 2
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
Diameter18 mm
Equipment protection level Dc (tc)IECEx TUR 21.0018X
Equipment protection level Gc (ec)IECEx TUR 21.0017X
Equipment protection level Gc (ec) IECEx TUR 21.0017X Equipment protection level Dc (tc) IECEx TUR 21.0018XEquipment protection level Gc (ec) | IECEx TUR 21.0017X | Equipment protection level Dc (tc) | IECEx TUR 21.0018X
Equipment protection level Gc (ec) TÜV 20 ATEX 8523 X Equipment protection level Dc (tc) TÜV 20 ATEX 8524 XEquipment protection level Gc (ec) | TÜV 20 ATEX 8523 X | Equipment protection level Dc (tc) | TÜV 20 ATEX 8524 X
Hazardous Location2024322315005977 2024322315005859
Hazardous Location 2024322315005977 2024322315005859Hazardous Location | 2024322315005977 2024322315005859
Hazardous Location 23-AV4BO-0237XHazardous Location | 23-AV4BO-0237X
Housing materialStainless steel 1.4305 / AISI 303
HysteresisH | 1 ... 10 % typ. 5 %
Installationnon-flush
LengthL | 2 m
Length 56 mm Diameter 18 mmLength | 56 mm | Diameter | 18 mm
Mass109 g
MaterialPVC
Mission Time (T M )20 a
MTTF d1581 a
Number of cores2
Output polarityDC
Output typeTwo-wire with minimum off-state current
Rated operating distances n | 8 mm
Reduction factor r 3040.7
Reduction factor r Al0.4
Reduction factor r Cu0.35
Reverse polarity protectionyes
Scope of delivery2 self locking nuts in scope of delivery
Sensing facePBT
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorall direction LED, yellow
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 30 mA
Use in the hazardous areasee instruction manuals
Wire end ferrulesyes

Documents

No documents are linked to this part yet.