All alternatives

View full report

Technical parameters

Power
Nominal voltageU o | 8.2 V (R i approx. 1 kΩ)
AC and DC characteristics
Switching frequencyf | 0 ... 650 Hz
Environment and package
Ambient temperature-25 ... 80 °C (-13 ... 176 °F)
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Other
Actual operating distances r | 9 ... 11 mm typ.
ANZEx18.3018X
Assured operating distances a | 0 ... 8.1 mm
Bending radius> 7.5 x cable diameter
Cable diameter6.7 mm ± 0.3 mm
CML approvalon request
Colorblue
Connection typecable
Control drawing116-0452
Core cross section0.5 mm 2
Degree of protectionIP66 / IP67
Diagnostic Coverage (DC)0 %
Diameter30 mm
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level GaIECEx PTB 11.0037X
Equipment protection level Ga PTB 00 ATEX 2048 X Equipment protection level Gb PTB 00 ATEX 2048 X Equipment protection level Da PTB 00 ATEX 2048 XEquipment protection level Ga | PTB 00 ATEX 2048 X | Equipment protection level Gb | PTB 00 ATEX 2048 X | Equipment protection level Da | PTB 00 ATEX 2048 X
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level MbIECEx PTB 11.0037X
Hazardous LocationE501628
Housing materialStainless steel 1.4305 / AISI 303
HysteresisH | 1 ... 10 % typ. 5 %
Installationflush
LengthL | 10 m
Length 40 mm Diameter 30 mmLength | 40 mm | Diameter | 30 mm
MaterialPUR
Measuring plate detected≤ 1 mA
Measuring plate not detectedmin. 3 mA
Measuring plate not detected min. 3 mA Measuring plate detected ≤ 1 mAMeasuring plate not detected | min. 3 mA | Measuring plate detected | ≤ 1 mA
Mission Time (T M )20 a
MTTF d1870 a
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN IEC 60947-5-2NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Standards | EN IEC 60947-5-2
NoteThe shield is not connected to the sensor.
Number of cores2
Ordinary LocationE87056
Ordinary Location E87056 Hazardous Location E501628 Control drawing 116-0452Ordinary Location | E87056 | Hazardous Location | E501628 | Control drawing | 116-0452
Output typeNAMUR
Rated operating distances n | 10 mm
Reduction factor r 3040.72
Reduction factor r Al0.32
Reduction factor r Cu0.32
Reverse polarity protectionreverse polarity protected
Scope of delivery2 self locking nuts in scope of delivery
Sensing facePBT
Short-circuit protectionyes
StandardsEN IEC 60947-5-2
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Switching functionNormally closed (NC)
Switching state indicatorLED, yellow
UL approvalcULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Use in the hazardous areasee instruction manuals
Wire end ferrulesyes

Documents

No documents are linked to this part yet.