| Power | |
|---|---|
| Nominal voltage | U o | 8.2 V (R i approx. 1 kΩ) |
| AC and DC characteristics | |
| Switching frequency | f | 1.5 kHz |
| Environment and package | |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Other | |
| Actual operating distance | s r | 0.9 ... 1.1 mm typ. |
| ANZEx | 18.3018X |
| Assured operating distance | s a | 0 ... 0.81 mm |
| CML approval | on request |
| Connection type | Connector plug |
| Degree of protection | IP67 |
| Diameter | 10 mm |
| Equipment protection level Da | IECEx PTB 11.0037X |
| Equipment protection level Gb | IECEx PTB 11.0037X |
| Equipment protection level Gb IECEx PTB 11.0037X Equipment protection level Da IECEx PTB 11.0037X Equipment protection level Mb IECEx PTB 11.0037X | Equipment protection level Gb | IECEx PTB 11.0037X | Equipment protection level Da | IECEx PTB 11.0037X | Equipment protection level Mb | IECEx PTB 11.0037X |
| Equipment protection level Gb PTB 00 ATEX 2048 X Equipment protection level Da PTB 00 ATEX 2048 X | Equipment protection level Gb | PTB 00 ATEX 2048 X | Equipment protection level Da | PTB 00 ATEX 2048 X |
| Equipment protection level Mb | IECEx PTB 11.0037X |
| Housing material | brass, nickel-plated |
| Hysteresis | H | 1 ... 10 % typ. 5 % |
| Installation | flush |
| Length | 73 mm |
| Length 73 mm Diameter 10 mm | Length | 73 mm | Diameter | 10 mm |
| Measuring plate detected | ≤ 1 mA |
| Measuring plate not detected | min. 3 mA |
| Measuring plate not detected min. 3 mA Measuring plate detected ≤ 1 mA | Measuring plate not detected | min. 3 mA | Measuring plate detected | ≤ 1 mA |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN IEC 60947-5-2 | NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Standards | EN IEC 60947-5-2 |
| Number of pins | 4 |
| Output type | NAMUR |
| Rated operating distance | s n | 1 mm |
| Reduction factor r 304 | 0.85 |
| Reduction factor r Al | 0.4 |
| Reduction factor r Cu | 0.3 |
| Sensing face | PBT |
| Standards | EN IEC 60947-5-2 |
| Switching function | Normally closed (NC) |
| Threading | M12 x 1 |
| Threading M12 x 1 Number of pins 4 | Threading | M12 x 1 | Number of pins | 4 |
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Use in the hazardous area | see instruction manuals |