Power
Nominal voltageU o | 8.2 V (R i approx. 1 kΩ)
AC and DC characteristics
Switching frequencyf | 0 ... 150 Hz
Environment and package
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Other
Assured operating distances a | 0 ... 4.05 mm
Bending radius> 10 x cable diameter
Cable diameter6.8 mm ± 0.2 mm
Cable diameter 6.8 mm ± 0.2 mm Bending radius > 10 x cable diameter Material silicone Core cross section 0.75 mm 2 Length L 5 mCable diameter | 6.8 mm ± 0.2 mm | Bending radius | > 10 x cable diameter | Material | silicone | Core cross section | 0.75 mm 2 | Length | L | 5 m
Connection typecable
Control drawing116-0454
Core cross section0.75 mm 2
Degree of protectionIP68
Diagnostic Coverage (DC)0 %
Diameter30 mm
Equipment protection level DaIECEx PTB 11.0092X
Equipment protection level Dc (tc)IECEx TUR 21.0018X
Equipment protection level GaIECEx PTB 11.0092X
Equipment protection level GbIECEx PTB 11.0092X
Equipment protection level Gc (ec)IECEx TUR 21.0017X
Equipment protection level MbIECEx PTB 11.0092X
Hazardous LocationE501628
Hazardous Location 2020322315002308 2024322315005947 2024322315005860Hazardous Location | 2020322315002308 2024322315005947 2024322315005860
Housing materialCrastin (PBT), black
Installationflush in mild steel
LengthL | 5 m
Length 40 mm Diameter 30 mmLength | 40 mm | Diameter | 30 mm
Materialsilicone
Measuring plate detected≥ 3 mA
Measuring plate not detected≤ 1 mA
Measuring plate not detected ≤ 1 mA Measuring plate detected ≥ 3 mAMeasuring plate not detected | ≤ 1 mA | Measuring plate detected | ≥ 3 mA
Mission Time (T M )20 a
MTTF d11850 a
Noteonly for non-ferrous metal
Ordinary LocationE87056
Ordinary Location E87056 Hazardous Location E501628 Control drawing 116-0454Ordinary Location | E87056 | Hazardous Location | E501628 | Control drawing | 116-0454
Output typeNAMUR with safety function
Rated operating distances n | 5 mm
Reduction factor r 3040
Reduction factor r Al1
Reduction factor r Cu1
Safety Integrity Level (SIL)up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.
Scope of deliverySupplied with 2 nuts
Sensing faceCrastin (PBT), black
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Suitable for 2:1 technologyyes , with reverse polarity protection diode
Switching functionNormally open (NO)
UL approvalcULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Use in the hazardous areasee instruction manuals

Documents

No documents are linked to this part yet.