All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Nominal voltage | U o | 8.2 V (R i approx. 1 kΩ) |
| AC and DC characteristics | |
| Switching frequency | f | 0 ... 1500 Hz |
| Environment and package | |
| Ambient temperature | -50 ... 100 °C (-58 ... 212 °F) Safety application: -40 ... 100°C |
| Other | |
| Assured operating distance | s a | 0 ... 3.24 mm |
| Bending radius | > 10 x cable diameter |
| Cable diameter | 4.8 mm ± 0.2 mm |
| Cable diameter 4.8 mm ± 0.2 mm Bending radius > 10 x cable diameter Material silicone Core cross section 0.34 mm 2 Length L 15 m | Cable diameter | 4.8 mm ± 0.2 mm | Bending radius | > 10 x cable diameter | Material | silicone | Core cross section | 0.34 mm 2 | Length | L | 15 m |
| Connection type | cable |
| Control drawing | 116-0454 |
| Core cross section | 0.34 mm 2 |
| Degree of protection | IP68 |
| Diagnostic Coverage (DC) | 0 % |
| Diameter | 12 mm |
| Equipment protection level Da | IECEx PTB 11.0092X |
| Equipment protection level Dc (tc) | IECEx TUR 21.0018X |
| Equipment protection level Ga | IECEx PTB 11.0092X |
| Equipment protection level Gb | IECEx PTB 11.0092X |
| Equipment protection level Gc (ec) | IECEx TUR 21.0017X |
| Equipment protection level Mb | IECEx PTB 11.0092X |
| Hazardous Location | E501628 |
| Hazardous Location 2020322315002308 2024322315005947 2024322315005860 | Hazardous Location | 2020322315002308 2024322315005947 2024322315005860 |
| Housing material | Crastin (PBT), black |
| Installation | non-flush |
| Length | L | 15 m |
| Length 34 mm Diameter 12 mm | Length | 34 mm | Diameter | 12 mm |
| Material | silicone |
| Measuring plate detected | ≤ 1 mA |
| Measuring plate not detected | ≥ 3 mA |
| Measuring plate not detected ≥ 3 mA Measuring plate detected ≤ 1 mA | Measuring plate not detected | ≥ 3 mA | Measuring plate detected | ≤ 1 mA |
| Mission Time (T M ) | 20 a |
| MTTF d | 10660 a |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN IEC 60947-5-2 | NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Standards | EN IEC 60947-5-2 |
| Note | Security relevant only up to -40°C |
| Ordinary Location | E87056 |
| Ordinary Location E87056 Hazardous Location E501628 Control drawing 116-0454 | Ordinary Location | E87056 | Hazardous Location | E501628 | Control drawing | 116-0454 |
| Output type | NAMUR with safety function |
| Rated operating distance | s n | 4 mm |
| Reduction factor r 304 | 0.85 |
| Reduction factor r Al | 0.4 |
| Reduction factor r Cu | 0.3 |
| Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. |
| Scope of delivery | Supplied with 2 nuts |
| Sensing face | Crastin (PBT), black |
| Standards | EN IEC 60947-5-2 |
| Switching function | Normally closed (NC) |
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Use in the hazardous area | see instruction manuals |
Documents
No documents are linked to this part yet.