Technical parameters

Power
Current0 ... 20 mA short-circuit protected
Current limitI max | 22 mA
Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 VInput/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Number of channels4
Open loop voltageU s | min. 22.7 V
Power consumption3 W
Power dissipation2 W
Rated voltageU r | 12 V DC , only in connection with the power supplies FB92**
Test current0.4 mA
Test current 0.4 mA Short-circuit < 50 Ω Open-circuit < 0.2 mATest current | 0.4 mA | Short-circuit | < 50 Ω | Open-circuit | < 0.2 mA
Transmitter supply voltagemin. 15 V at 20 mA ; 21.5 V at 4 mA
AC and DC characteristics
Resolution12 Bit (0 ... 26 mA)
Environment and package
After calibration 0.1 % of the signal range at 20 °C (68 °F) Influence of ambient temperature 0.1 %/10 K of the signal rangeAfter calibration | 0.1 % of the signal range at 20 °C (68 °F) | Influence of ambient temperature | 0.1 %/10 K of the signal range
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Field device pressure converter Field device [2] flow converter Field device [3] level converter Field device [4] Temperature ConverterField device | pressure converter | Field device [2] | flow converter | Field device [3] | level converter | Field device [4] | Temperature Converter
Height107 mm
Height 107 mm Width 28 mm Depth 132 mmHeight | 107 mm | Width | 28 mm | Depth | 132 mm
Influence of ambient temperature0.1 %/10 K of the signal range
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Other
After calibration0.1 % of the signal range at 20 °C (68 °F)
ATEX approvalFIDI 21 ATEX 0013 U
Codingoptional mechanical coding via front socket
Connectionbackplane bus
Connection [2]volt-free contact
Connection [2] volt-free contactConnection [2] | volt-free contact
Connection 2-wire transmitterConnection | 2-wire transmitter
Connection mechanical switch with additional resistors (see connection diagram) Short-circuit > 7 mA Open-circuit < 0.1 mAConnection | mechanical switch with additional resistors (see connection diagram) | Short-circuit | > 7 mA | Open-circuit | < 0.1 mA
Damaging gasEN 60068-2-42
Degree of protectionIEC 60529
Depth132 mm
Directive 2014/30/EUEN 61326-1:2013
Directive 2014/30/EU EN 61326-1:2013Directive 2014/30/EU | EN 61326-1:2013
Directive 2014/34/EUEN 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018
Directive 2014/34/EU EN 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018Directive 2014/34/EU | EN 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018
Drive capability12 V / 22 mA
Electromagnetic compatibilityNE 21:2007
Environmental testEN 60068-2-14
EU-type examination certificateFIDI 21 ATEX 0013 U
Field devicepressure converter
Field device [2]flow converter
Field device [3]level converter
Field device [4]Temperature Converter
Field device Proportional Valve Field device [2] I/P converters Field device [3] on-site displayField device | Proportional Valve | Field device [2] | I/P converters | Field device [3] | on-site display
Field device Solenoid Valve Field device [2] audible alarm Field device [3] visual alarmField device | Solenoid Valve | Field device [2] | audible alarm | Field device [3] | visual alarm
HART communicationyes
HART secondary variableyes
IECEx certificateIECEx FIDI 21.0003U
IECEx certificate IECEx FIDI 21.0003U IECEx marking Ex db eb q IIC GbIECEx certificate | IECEx FIDI 21.0003U | IECEx marking | Ex db eb q IIC Gb
IECEx markingEx db eb q IIC Gb
Input resistance15 Ω
Interfacemanufacturer-specific bus to standard com unit
Internal resistorR i | 385 Ω
LED indicationPower LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Configuration LED (AI, AO, DI, DO) white: selected channel mode
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
Loadmax. 750 Ω at 20 mA
MarkingII 2G Ex db eb q IIC Gb
Marking II 2G Ex db eb q IIC GbMarking | II 2G Ex db eb q IIC Gb
Massapprox. 425 g
Occupied slots1
Open-circuitfactory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA
Refresh timeapprox. 100 ms (4 channels)
Relative humidityEN 60068-2-78
Shock resistanceEN 60068-2-27
Short-circuitfactory setting: > 21 mA Can be parameterized in the range 0 ... 22 mA
Short-circuit factory setting: < 50 Ω configurable between 0 ... 26 mA Open-circuit deviation of preset output value > 0.5 mAShort-circuit | factory setting: < 50 Ω configurable between 0 ... 26 mA | Open-circuit | deviation of preset output value > 0.5 mA
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Switching point: OFF< 1.2 mA
Switching point: ON> 2.1 mA
Switching point: ON > 2.1 mA Switching point: OFF < 1.2 mASwitching point: ON | > 2.1 mA | Switching point: OFF | < 1.2 mA
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Vibration resistanceEN 60068-2-6
Watchdogoutput off 0.5 s after serious fault
Width28 mm