| Power | |
|---|---|
| Current | 0 ... 20 mA short-circuit protected |
| Current limit | I max | 22 mA |
| Input/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V | Input/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Number of channels | 4 |
| Open loop voltage | U s | min. 22.7 V |
| Power consumption | 3 W |
| Power dissipation | 2 W |
| Rated voltage | U r | 12 V DC , only in connection with the power supplies FB92** |
| Test current | 0.4 mA |
| Test current 0.4 mA Short-circuit < 50 Ω Open-circuit < 0.2 mA | Test current | 0.4 mA | Short-circuit | < 50 Ω | Open-circuit | < 0.2 mA |
| Transmitter supply voltage | min. 15 V at 20 mA ; 21.5 V at 4 mA |
| AC and DC characteristics | |
| Resolution | 12 Bit (0 ... 26 mA) |
| Environment and package | |
| After calibration 0.1 % of the signal range at 20 °C (68 °F) Influence of ambient temperature 0.1 %/10 K of the signal range | After calibration | 0.1 % of the signal range at 20 °C (68 °F) | Influence of ambient temperature | 0.1 %/10 K of the signal range |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Field device pressure converter Field device [2] flow converter Field device [3] level converter Field device [4] Temperature Converter | Field device | pressure converter | Field device [2] | flow converter | Field device [3] | level converter | Field device [4] | Temperature Converter |
| Height | 107 mm |
| Height 107 mm Width 28 mm Depth 132 mm | Height | 107 mm | Width | 28 mm | Depth | 132 mm |
| Influence of ambient temperature | 0.1 %/10 K of the signal range |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Other | |
| After calibration | 0.1 % of the signal range at 20 °C (68 °F) |
| ATEX approval | FIDI 21 ATEX 0013 U |
| Coding | optional mechanical coding via front socket |
| Connection | backplane bus |
| Connection [2] | volt-free contact |
| Connection [2] volt-free contact | Connection [2] | volt-free contact |
| Connection 2-wire transmitter | Connection | 2-wire transmitter |
| Connection mechanical switch with additional resistors (see connection diagram) Short-circuit > 7 mA Open-circuit < 0.1 mA | Connection | mechanical switch with additional resistors (see connection diagram) | Short-circuit | > 7 mA | Open-circuit | < 0.1 mA |
| Damaging gas | EN 60068-2-42 |
| Degree of protection | IEC 60529 |
| Depth | 132 mm |
| Directive 2014/30/EU | EN 61326-1:2013 |
| Directive 2014/30/EU EN 61326-1:2013 | Directive 2014/30/EU | EN 61326-1:2013 |
| Directive 2014/34/EU | EN 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 |
| Directive 2014/34/EU EN 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 | Directive 2014/34/EU | EN 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 |
| Drive capability | 12 V / 22 mA |
| Electromagnetic compatibility | NE 21:2007 |
| Environmental test | EN 60068-2-14 |
| EU-type examination certificate | FIDI 21 ATEX 0013 U |
| Field device | pressure converter |
| Field device [2] | flow converter |
| Field device [3] | level converter |
| Field device [4] | Temperature Converter |
| Field device Proportional Valve Field device [2] I/P converters Field device [3] on-site display | Field device | Proportional Valve | Field device [2] | I/P converters | Field device [3] | on-site display |
| Field device Solenoid Valve Field device [2] audible alarm Field device [3] visual alarm | Field device | Solenoid Valve | Field device [2] | audible alarm | Field device [3] | visual alarm |
| HART communication | yes |
| HART secondary variable | yes |
| IECEx certificate | IECEx FIDI 21.0003U |
| IECEx certificate IECEx FIDI 21.0003U IECEx marking Ex db eb q IIC Gb | IECEx certificate | IECEx FIDI 21.0003U | IECEx marking | Ex db eb q IIC Gb |
| IECEx marking | Ex db eb q IIC Gb |
| Input resistance | 15 Ω |
| Interface | manufacturer-specific bus to standard com unit |
| Internal resistor | R i | 385 Ω |
| LED indication | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Configuration LED (AI, AO, DI, DO) white: selected channel mode |
| Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool |
| Load | max. 750 Ω at 20 mA |
| Marking | II 2G Ex db eb q IIC Gb |
| Marking II 2G Ex db eb q IIC Gb | Marking | II 2G Ex db eb q IIC Gb |
| Mass | approx. 425 g |
| Occupied slots | 1 |
| Open-circuit | factory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA |
| Refresh time | approx. 100 ms (4 channels) |
| Relative humidity | EN 60068-2-78 |
| Shock resistance | EN 60068-2-27 |
| Short-circuit | factory setting: > 21 mA Can be parameterized in the range 0 ... 22 mA |
| Short-circuit factory setting: < 50 Ω configurable between 0 ... 26 mA Open-circuit deviation of preset output value > 0.5 mA | Short-circuit | factory setting: < 50 Ω configurable between 0 ... 26 mA | Open-circuit | deviation of preset output value > 0.5 mA |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
| Switching point: OFF | < 1.2 mA |
| Switching point: ON | > 2.1 mA |
| Switching point: ON > 2.1 mA Switching point: OFF < 1.2 mA | Switching point: ON | > 2.1 mA | Switching point: OFF | < 1.2 mA |
| System information | The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. |
| Vibration resistance | EN 60068-2-6 |
| Watchdog | output off 0.5 s after serious fault |
| Width | 28 mm |