Pepperl+Fuchs, Inc.Germany
102115
ActiveRetroreflective sensor with polarization filter for clear object detection
All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| No-load supply current | I 0 | < 20 mA at 24 V DC |
| Operating voltage | U B | 10 ... 30 V DC , class 2 |
| Switching current | max. 100 mA |
| Switching voltage | max. 30 V DC |
| AC and DC characteristics | |
| Ripple | max. 10 % |
| Switching frequency | f | 1000 Hz |
| Environment and package | |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Height | 38 mm |
| Height 38 mm Width 23 mm Depth 11 mm | Height | 38 mm | Width | 23 mm | Depth | 11 mm |
| Storage temperature | -40 ... 75 °C (-40 ... 167 °F) |
| Other | |
| Ambient light limit | 40000 Lux |
| Angle deviation | max. ± 1° |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Connection | M8 x 1 connector, 4-pin |
| Connector | plastic |
| Contrast detection levels | 15 % - clear glass bottles |
| Control elements | Teach-In key |
| Degree of protection | IP67 |
| Depth | 11 mm |
| Diagnostic Coverage (DC) | 0 % |
| Diameter of the light spot | approx. 40 mm at detection range 1 m |
| Effective detection range | 0 ... 3.5 m in TEACH mode |
| Function indicator | LED yellow: switching state ; Operating reserve ; Teach-In |
| Housing | PC (glass-fiber-reinforced Makrolon) |
| Housing PC (glass-fiber-reinforced Makrolon) Optical face glass Connector plastic | Housing | PC (glass-fiber-reinforced Makrolon) | Optical face | glass | Connector | plastic |
| Light source | LED |
| Light type | modulated visible red light , 660 nm |
| Mass | approx. 25 g |
| Mission Time (T M ) | 20 a |
| MTTF d | 1050 a |
| Opening angle | 1.7 ° |
| Operation indicator | LED green, statically lit Power on , Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) , short-circuit : LED green flashing (approx. 4 Hz) |
| Optical face | glass |
| Polarization filter | yes |
| Product standard | EN 60947-5-2 |
| Protection class | II, rated voltage ≤ 50 V AC with pollution degree 1-2 according to IEC 60664-1 functional insulation acc. to DIN EN 50178 |
| Reference target | H85-2 reflector |
| Reflector distance | 0 ... 3.5 m in TEACH mode |
| Response time | 500 µs |
| Signal output | 1 NPN, short-circuit protected open collector |
| Switching type | light/dark on, switchable |
| UL approval | cULus |
| Width | 23 mm |
Documents
No documents are linked to this part yet.