All alternatives

View full report

Technical parameters

Power
Operating voltageU B | 24 V DC +/- 20 %
Power consumptionP 0 | primary sensor 3.6 W secondary sensor 3.4 W
Switching currentmax. 100 mA
Switching voltagemax. 30 V DC
Environment and package
Ambient temperature-30 ... 60 °C (-22 ... 140 °F)
DIP switch switch 1 ON switch 2 ON switch 3 ON switch 4 ON Adjuster Adjustment dial: position 6 = installation height 2100 mmDIP switch | switch 1 ON switch 2 ON switch 3 ON switch 4 ON | Adjuster | Adjustment dial: position 6 = installation height 2100 mm
Height61.3 mm
Height 61.3 mm Depth 38.7 mm Length 255 mmHeight | 61.3 mm | Depth | 38.7 mm | Length | 255 mm
Mounting height1500 ... 2500 mm (0.5 m ... 1.8 m door width) 2500 ... 3000 mm (0.5 m ... 1.6 m door width)
Storage temperature-30 ... 70 °C (-22 ... 158 °F)
Other
AdjusterAdjustment dial: position 6 = installation height 2100 mm
CategoryCat. 2
ConnectionPlug with connection cable , 8-wire
Control elementsTeach-In key , DIP switch for selection of operating modes
Degree of protectionIP65
Depth38.7 mm
Diagnostic Coverage (DC)94 %
Diameter of the light spot8 cm at 2000 mm sensor range
DIP switchswitch 1 ON switch 2 ON switch 3 ON switch 4 ON
Functional safetyISO 13849-1 ; EN 61508 part1-4
Function indicatorStatus LED red/green/orange Teach-in, errors, switch state LED red: Switch indicator for door hinge side LED green: Switch indicator for hinge opposite side
HousingPC (Polycarbonate)
Housing PC (Polycarbonate) Optical face PC (Polycarbonate)Housing | PC (Polycarbonate) | Optical face | PC (Polycarbonate)
Length255 mm
Light sourceIRED 850 nm
Massapprox. 500 g (kit)
MTTF d> 100 a
Number of beams20
Optical facePC (Polycarbonate)
Performance level (PL)PL d
Product standardEN 12978 ; EN 16005 ; DIN 18650
Protection classIII
Relative humidity25% ... 95% , non-condensing
Response time≤ 50 ms with installation height ≤ 2500 mm ≤ 80 ms with installation height > 2500 mm
Safety Integrity Level (SIL)SIL 2
Scope of deliverySensor system for hinge side and leading edge side (1 primary sensor and 1 secondary sensor, connecting cable, door transition cable, corrugated hose with wall bracket, 2 x 3 self-tapping screws, drilling template, cable seal with IP65 degree of protection)
Signal outputNPN , PNP , short-circuit protected , switchable
Switching typeswitching when protection field is clear
Test inputHigh at U = 10 V DC ... 30 V DC Low at U = < 2 V DC
TÜV approvalTÜV NORD

Documents

No documents are linked to this part yet.