All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| No-load supply current | I 0 | ≤ 10 mA |
| Off-state current | I r | max. 20 µA |
| Operating current | I L | 0 ... 200 mA |
| Operating voltage | U B | 6 ... 36 V |
| Rated impulse withstand voltage | U imp | 500 V |
| Rated insulation voltage | U i | 36 V |
| Rated insulation voltage U i 36 V Rated impulse withstand voltage U imp 500 V | Rated insulation voltage | U i | 36 V | Rated impulse withstand voltage | U imp | 500 V |
| Voltage drop | U d | ≤ 1 V |
| AC and DC characteristics | |
| Switching frequency | f | 0 ... 2550 Hz |
| Time delay before availability | t v | ≤ 10 ms |
| Environment and package | |
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mounting | with nuts, M12 |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Other | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm |
| Assured operating distance | s a | 0 ... 3.24 mm |
| Bending radius | > 10 x cable diameter |
| Cable diameter | 4.3 mm ± 0.15 mm |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Color | black |
| Connection type | cable |
| Core cross section | 0.34 mm 2 |
| Degree of protection | IP65 / IP66 / IP67 / IP68 / IP69 |
| Diagnostic Coverage (DC) | 0 % |
| Diameter | 12 mm |
| Housing material | brass , white bronze coated |
| Hysteresis | H | typ. 5 % |
| Installation | flush |
| Length | L | 2 m |
| Length 53 mm Diameter 12 mm | Length | 53 mm | Diameter | 12 mm |
| Marine approval | DNVGL TAA00003AK |
| Mass | 86 g |
| Material | PVC |
| Mission Time (T M ) | 20 a |
| MTTF d | 1607 a |
| Number of cores | 3 |
| Output polarity | DC |
| Output type | PNP |
| Protection class | II |
| PWIS conformity | VDMA 24364-C1/T100°C-W |
| Rated operating distance | s n | 4 mm |
| Reduction factor r 304 | 0.79 |
| Reduction factor r Al | 0.4 |
| Reduction factor r Brass | 0.49 |
| Reduction factor r Cu | 0.35 |
| Reverse polarity protection | reverse polarity protected |
| Scope of delivery | 2 self locking nuts in scope of delivery |
| Sensing face | PBT , green |
| Short-circuit protection | pulsing |
| Standards | EN IEC 60947-5-2 |
| Standards EN IEC 60947-5-2 | Standards | EN IEC 60947-5-2 |
| Switching function | Normally closed (NC) |
| Switching state indicator | LED, yellow |
| Tightening torque | ≤ 10 Nm |
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 36 V DC Output Switching Current: 200 mA |
| Wire end ferrules | yes |
Documents