| Power | |
|---|---|
| Current consumption | 30 mA |
| Operating current | I L | 0.5 mA |
| Operating voltage | U B | 10 ... 12 V |
| Voltage drop | U d | 7 V @ 10 K load, 12 V supply |
| Environment and package | |
| Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Other | |
| Bending radius | > 10 x cable diameter |
| Cable diameter | 6.35 mm ± 0.4 mm |
| CE conformity | 2014/30/EU |
| Color | yellow |
| Connection type | cable |
| Core cross section | 0.34 mm 2 |
| Degree of protection | IP69K |
| Depth | 12.7 mm |
| Housing material | 316 stainless steel |
| Installation | non-flush |
| Length | L | 15 m |
| Material | PVC |
| Note | Only approved for use with FYQLA1-140R-3 and KE5D2-6H/2R-S Use only with actuator 52FY31-V4A |
| Number of cores | 4 |
| Output polarity | DC |
| Output type | PNP/NPN |
| Rated operating distance | s n | 2.5 mm at 0 mm offset, 1.3 mm at 3.5 mm offset, 0 mm at 4.0 mm offset |
| Sensing face | 316 stainless steel |
| Short-circuit protection | NO |
| Standards | IEC 60947-5-2:2012 IEC 60947-5-3:2013 IEC 61236-3-1:2008 |
| Standards IEC 60947-5-2:2012 IEC 60947-5-3:2013 IEC 61236-3-1:2008 | Standards | IEC 60947-5-2:2012 IEC 60947-5-3:2013 IEC 61236-3-1:2008 |
| Switching function | Normally open (NO) |
| UL approval | cULus Listed, General Purpose |
| Width | 39 mm |
| Width 39 mm Depth 12.7 mm Length 39 mm | Width | 39 mm | Depth | 12.7 mm | Length | 39 mm |
| Wire end ferrules | yes |