42519

42519

在产

LCD batch controller with 2 relay outputs and 90 ... 260 V<sub>AC</sub> supply voltage

问 AI FAE

全部替代型号

查看完整报告

技术参数

电源
Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2
Low Voltage Directive 2006/95/EC EN 61010-1:2001; protection class: 2 EMC Directive 2004/108/EC EN 61000-6-2:2005, EN 50295:1999Low Voltage Directive 2006/95/EC | EN 61010-1:2001; protection class: 2 | EMC Directive 2004/108/EC | EN 61000-6-2:2005, EN 50295:1999
Operating voltageU B | 90 ... 260 V AC
Power consumptionP 0 | max. 8 VA
Sensor supply20.4 ... 27.6 V DC, max. 80 mA
Switching currentmax. 3 A AC/DC, min. 30 mA DC,
Switching powermax. 750 VA / 90 W
Switching voltagemax. 250 V AC / 110 V DC
Switching voltage max. 250 V AC / 110 V DC Switching current max. 3 A AC/DC, min. 30 mA DC, Switching power max. 750 VA / 90 WSwitching voltage | max. 250 V AC / 110 V DC | Switching current | max. 3 A AC/DC, min. 30 mA DC, | Switching power | max. 750 VA / 90 W
交流 / 直流特性
Counting frequency30 Hz / 55 kHz
Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 %
Impedance5 kOhm
环境与封装
Ambient temperature-20 ... 65 °C (-4 ... 149 °F)
Dimensions48 mm x 48 mm x 109.8 mm
Storage temperature-25 ... 75 °C (-13 ... 167 °F)
其他
Altitude0 ... 2000 m
ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI
Data storage> 10 years, EEPROM
Decimal point0 to max 5 fractional digits
Degree of protectionIP65 (front)
Display valuedigit height 9 mm
Electrical life1 x 10 5 switching cycles at 3 A
EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999
Emitted interferenceDIN EN 55011:2009, Class B
Fusing90 … 260 V AC: T 0.1 A
High12 ... 30 V DC
High 12 ... 30 V DC Low 0 ... 4 V DCHigh | 12 ... 30 V DC | Low | 0 ... 4 V DC
Key interlockvia "high" potential at "LOCK" input
Low0 ... 4 V DC
Massapprox. 143 g
Mechanical life2 x 10 7 switching cycles
Mechanical life 2 x 10 7 switching cycles Electrical life 1 x 10 5 switching cycles at 3 AMechanical life | 2 x 10 7 switching cycles | Electrical life | 1 x 10 5 switching cycles at 3 A
Mechanical life 2 x 10 7 switching cycles Electrical life 5 x 10 4 cycles at 3 AMechanical life | 2 x 10 7 switching cycles | Electrical life | 5 x 10 4 cycles at 3 A
Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction
Minimum pulse durationControl/reset inputs: 10 ms / 1 ms
Output IRelay with make contact, NC or NO progr.
Output IIRelay with changeover contact
Pollution degree2
Pre-selection2-fold
Programmingkeypad-driven menu
Pulse counterCounting with counting direction (cnt.dir), difference counting (up.dn), up/down counting (quad), Cumulative counting (up.up), up/down counting x 2 (quad 2), up/down counting x 4 (quad 4), additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%
Relative humidity≤ 93 % at 40 °C (non-condensing)
Relaychangeover contact , Make contact
Resetmanually or external
Response timeRelay: approx. 7 ms Frequency counter: 100/600 ms
Scale factor0.0001 ... 99.9999
Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ 3 times in each direction
TimerTime measurement via GATE input (FrErun), counter input A: Start, counter input B: Stop (InpA.InpB.), counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto)
Type2-line, 2 x 6-digit LC display with leading sign backlighted

器件图片

技术资料

该型号暂未收录资料。