1739

1739

在产

Thru-beam sensor, 20 m detection range, infrared light, light/dark on, AC/DC version, relay contact output, sensitivity adjuster, terminal compartment

问 AI FAE

全部替代型号

查看完整报告

技术参数

电源
No-load supply currentI 0 | ≤ 60 mA receiver and emitter
Operating voltageU B | 12 ... 240 V DC / 24 ... 240 V AC (50 ... 60 Hz)
Power consumptionP 0 | ≤ 3 VA
Switching currentmax. 3 A
Switching powerDC: max. 90 W AC: max. 750 VA
Switching voltagemax. 240 V AC ; 150 V DC
交流 / 直流特性
Ripple10 %
Switching frequencyf | ≤ 25 Hz
Time delay before availabilityt v | ≤ 300 ms
环境与封装
Ambient temperature-25 ... 55 °C (-13 ... 131 °F)
Height64 mm
Height 64 mm Width 25 mm Depth 75 mmHeight | 64 mm | Width | 25 mm | Depth | 75 mm
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
其他
Adjustment range2 ... 25 m
Ambient light limitIEC / EN 60947-5-2 , 10000 Lux
ApprovalsCE
CCC approvalCertified by China Compulsory Certification (CCC)
Connectionterminal compartment PG9 , ≤ 0.75 mm 2
Control elementsSensing range adjuster, light-on/dark-on changeover switch
Degree of protectionIP54
Depth75 mm
Diagnostic Coverage (DC)0 %
Effective detection range0 ... 20 m
EmitterLA39/116
Function indicatorLED yellow: switching state LED red: pre-fault indication
HousingPBT
Housing PBT Optical face PMMAHousing | PBT | Optical face | PMMA
Light sourceIRED
Light typemodulated infrared light
MassEmitter: approx. 90 g receiver: approx. 110 g
Mission Time (T M )20 a
MTTF d916 a
Operation indicatorLED red (emitter)
Optical facePMMA
Product standardEN 60947-5-2
Protection classII, rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Caution! The protection class 2 is only valid when the terminal compartment is closed. output circuit has basic insulation to control circuit according to IEC/EN 61140
ReceiverLK39/31/40a/116
Reference targetreceiver
Response time≤ 20 ms
Scope of deliveryMounting aid
Signal output1 relay output
Switching typelight/dark on
Threshold detection range25 m
Width25 mm

器件图片

技术资料

该型号暂未收录资料。