103951

103951

在产

Inductive sensor

查看国产替代问 AI FAE

全部替代型号

查看完整报告

技术参数

电源
Nominal voltageU o | 8.2 V (R i approx. 1 kΩ)
交流 / 直流特性
Switching frequencyf | 0 ... 1500 Hz
环境与封装
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
其他
ANZEx18.3018X
Assured operating distances a | 0 ... 3.24 mm
Bending radius> 10 x cable diameter
Cable diameter4.8 mm ± 0.2 mm
Cable diameter 4.8 mm ± 0.2 mm Bending radius > 10 x cable diameter Material PVC Core cross section 0.34 mm 2 Length L 10 mCable diameter | 4.8 mm ± 0.2 mm | Bending radius | > 10 x cable diameter | Material | PVC | Core cross section | 0.34 mm 2 | Length | L | 10 m
CML approvalon request
Connection typecable
Core cross section0.34 mm 2
Degree of protectionIP66 / IP68
Diagnostic Coverage (DC)0 %
Diameter12 mm
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level Gb IECEx PTB 11.0037X Equipment protection level Da IECEx PTB 11.0037X Equipment protection level Mb IECEx PTB 11.0037XEquipment protection level Gb | IECEx PTB 11.0037X | Equipment protection level Da | IECEx PTB 11.0037X | Equipment protection level Mb | IECEx PTB 11.0037X
Equipment protection level Gb PTB 00 ATEX 2048 X Equipment protection level Da PTB 00 ATEX 2048 XEquipment protection level Gb | PTB 00 ATEX 2048 X | Equipment protection level Da | PTB 00 ATEX 2048 X
Equipment protection level MbIECEx PTB 11.0037X
Hazardous Location2020322315002255
Hazardous Location 2020322315002255Hazardous Location | 2020322315002255
Housing materialPBT
Installationnon-flush
LengthL | 10 m
Length 35 mm Diameter 12 mmLength | 35 mm | Diameter | 12 mm
MaterialPVC
Measuring plate detected≤ 1 mA
Measuring plate not detectedmin. 3 mA
Measuring plate not detected min. 3 mA Measuring plate detected ≤ 1 mAMeasuring plate not detected | min. 3 mA | Measuring plate detected | ≤ 1 mA
Mission Time (T M )20 a
MTTF d11774 a
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN IEC 60947-5-2NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Standards | EN IEC 60947-5-2
Output typeNAMUR
Rated operating distances n | 4 mm
Reduction factor r 3040.85
Reduction factor r Al0.4
Reduction factor r Cu0.3
Safety Integrity Level (SIL)SIL 2
Scope of deliverySupplied with 2 nuts
Sensing facePBT
StandardsEN IEC 60947-5-2
Switching functionNormally closed (NC)
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Use in the hazardous areasee instruction manuals

器件图片