101131

101131

在产

G20 MDR module with AS-Interface for 4 digital inputs and 2 connections for MDRs

查看国产替代问 AI FAE

全部替代型号

查看完整报告

技术参数

电源
Auxiliary voltage (output)U AUX | 18 ... 30 VDC PELV
Current3.5 A continuous current , 5 A (<2 s) , max. 7.5 A (<0,3 s) per motor
Current loading capacity500 mA , overload and short-circuit protected
Input current≤ 8 mA (limited internally)
Rated operating currentI e | ≤ 35 mA
Rated operating voltageU e | 26.5 ... 31.6 V from AS-Interface
Supplyfrom external auxiliary voltage U AUX
交流 / 直流特性
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Signal delay< 1 ms (input/AS-Interface)
环境与封装
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Height27.5 mm
Height 27.5 mm Width 135.5 mm Length 54 mmHeight | 27.5 mm | Width | 135.5 mm | Length | 54 mm
Mounting2 clips with ∅ 8 mm drill hole
Storage temperature-30 ... 85 °C (-22 ... 185 °F)
其他
AS-InterfaceEN 62026-2:2013
AS-Interface specificationV3.0
Cable length0.35 m
Compatible roller motorsInterroll EC310 Interroll EC5000 24 V AI (20 W / 35 W / 50 W) Rulmeca BL3 Itoh Denki PM500XK Itoh Denki PM500XC PULSEROLLER Senergy-IDC MTA MRD50 (A interface, 24 V to 40 W) WWL R-*-H + CE23XX Conveline RM50
ConnectionAS-Interface, AUX: Insulation piercing technology Yellow flat cable/black flat cable Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104 Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded) Matching connector: LM004-Gx1-A or similar Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded). Matching connector: NM005-Sx1-B or similar
Degree of protectionEN 60529:2000
Directive 2014/30/EUEN 62026-2:2013
Directive 2014/30/EU EN 62026-2:2013Directive 2014/30/EU | EN 62026-2:2013
Emitted interferenceEN 61000-6-4:2007
Fieldbus standardEN 62026-2:2013
ID1 code6
ID2 codeE
ID codeA
InputEN 61131-2:2007
Input filter2 ms
IO code7
IO code 7 ID code A ID1 code 6 ID2 code EIO code | 7 | ID code | A | ID1 code | 6 | ID2 code | E
LED AUXext. auxiliary voltage U AUX ; dual LED green/red green: voltage OK red: reverse voltage
LED DIRMotor rotation direction; yellow LED
LED ERRMotor fault: 2 LED yellow
LED FAULTerror display; LED red red: communication error or address is 0 red flashing: overload of sensor supply or external auxiliary voltage U AUX missing
LED FUSEMotor power supply; 2 green LEDs
LED INswitching state (input); 2 LED yellow
LED MOTMotor active; 2 yellow LEDs
LED PWRAS-Interface voltage; green LED green: voltage OK green flashing: address 0 or sensor supply overload or external auxiliary voltage U AUX missing
Length54 mm
Mass220 g
Motor faultDigital input NPN, U 0 = 3.3 V, R i = 52 kΩ 0 (no error) ≥ 40 µA 1 (error) ≤ 30 µA
MTBF98 a
Node typeA/B node
NoteThe flat cable routing is designed for 100 actuation cycles
Number/Type2 Inputs for 3-wire sensors (PNP), DC
Overload protectionFuse 5 A, I 2 t = 53.7 A 2 s per motor
ProfileS-7.A.E
Required gateway specification≥ V2.1
Rotation direction signalU D | Off / ≥ (U AUX - 1.0 V) at no-load R i = 5.6 kΩ, R LOAD ≥ 5 kΩ AS-Interface data bit D2 = 0: U D = Off
Switching pointaccording to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA 1 (damped) ≥ 2.0 mA
UL File NumberE223772 "For use in NFPA 79 Applications only"
Velocity signalU S | 1.4 … 13 V at no-load R i = 5.6 kΩ, R LOAD ≥ 35 kΩ Control via parameter P2:0
Width135.5 mm

器件图片

技术资料

该型号暂未收录资料。