All alternatives

View full report

Technical parameters

Power
1) Voltage Rating600 V RMS
Environment and package
1) Temperature Range-25 to 90°C(static), -5 to 90°C (dynamic)
Other
1) Component 14 X 1 COND
(1) PrintALPHANUMERIC NUMBERS - 1-ONE ALTERNATING AND INVERTED
2) Bend Radius10X Cable Diameter(static), 15X Cable Diameter(dynamic)
2) Cable Assembly4 Components Cabled
2) Capacitance55 pF/ft @1 kHz, Nominal Conductor to Conductor
(2) Color CodeAlpha Wire Color Code KX
3) CEEU Low Voltage Directive 2014/35/EU
3) Ground Capacitance99 pF/ft @1 kHz, Nominal
3) Pull Tension420 Lbs, Maximum
3) ShieldA/P/A Tape, 25% Overlap, Min.
4) Inductance0.16 μH/ft, Nominal
5) Conductor DCR1.02 Ω/1000ft @20°C, Nominal
6) OA Shield DCR0.71 Ω/1000ft @20°C, Nominal
a) Color(s)BLACK
a) Drain Wire4 x 16 (26/30) AWG Tinned Copper
a) Twists2.1 Twists/foot (min)
b) BraidTinned Copper,70% Coverage, Min.
b) Jacket SeparatorTissue Tape, 25% Overlap, Min.
b) OrientationComponents to be arranged from INSIDE LAYER to OUTSIDE LAYER
c) Core WrapClear Mylar Tape, 25% Overlap, Min.
ColorGREEN/YELLOW
Cond1
c) PrintALPHA WIRE-* P/N 5663 4C 10 AWG XTRAGUARD(R) MOTOR SUPPLY CABLE - EXXXXXX (UL) WTTC 1000V 90C OR (UL) TC-ER 600V 90C DRY 75C WET SUN RES DIR BUR OR MTW 10 AWG OR CRU AWM I/II A/B 90C 600V FT4 CE ROHS (SEQ FOOTAGE) * = Factory Code
Electrical Properties(For Engineering purposes only)
MTW90°C Dry / 60°C Wet / 600 V RMS
PackagingFlange x Traverse x Barrel (inches)
TCEXPOSED RUN
WTTC90°C / 1000 V RMS

Documents