52081

52081

在产

1001A Series purge and pressurization system

查看国产替代问 AI FAE

全部替代型号

查看完整报告

技术参数

电源
Output type Switch contacts Contact loading 120/220 VAC; 24 VDC @ 10 A; 125 VDC @ 50 mA power requirements: 24 / 120 / 240 VDC @ 3 / 4 / 11 wattsOutput type | Switch contacts | Contact loading | 120/220 VAC; 24 VDC @ 10 A; 125 VDC @ 50 mA power requirements: 24 / 120 / 240 VDC @ 3 / 4 / 11 watts
Protective gas supplyinstrument grade air or inert gas
环境与封装
Ambient temperature-29 ... 49 °C (-20.2 ... 120.2 °F)
其他
ConnectionTerminal blocks
Connection typeSystem supply fitting: 1/4" tube fitting Enclosure supply fitting: 1/4" tube fitting Enclosure reference fitting: 1/4" tube fitting Switch conduit port size: 1/2" FPT
Contact loading120 VAC @ 15 A
cULusType Y LPS: Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, and G WPS: Class I, Division 1, Groups C, D; Class II, Division 1, Groups E, F, and G WPSA: Class I, Division 1, Groups A, B, C, D Type Z LPS: Class I, Division 2, Groups A, B, C, D; Class II, Division 2, Groups E, F, and G WPS: Class I, Division 2, Groups C, D; Class II, Division 2, Groups E, F, and G WPSA: Class I, Division 2, Groups A, B, C, D
FM approvalType Y LPS: Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, and G WPS: Class I, Division 1, Groups C, D; Class II, Division 1, Groups E, F, and G WPSA: Class I, Division 1, Groups A, B, C, D Type Z LPS: Class I, Division 2, Groups A, B, C, D; Class II, Division 2, Groups E, F, and G WPS: Class I, Division 2, Groups C, D; Class II, Division 2, Groups E, F, and G WPSA: Class I, Division 2, Groups A, B, C, D
Hazardous environmentgas or dust
Mass1001A-LPS-* 2.3 kg (5 lb) 1001A-WPS* 4.5 kg (10 lb)
MaterialRegulator body: zinc w/enamel finish Regulator handle: polycarbonate Enclosure pressure gauge: alum. w/enamel finish Tube fitting: 316 ss forged body Tubing: 316 ss 1/4" .035 welded System nameplate: silk screened Lexan ® & ss Fastener hardware: alum. & stainless steel Mounting plate: 316 14 ga #3 brush ss EXP pressure switch body: anodized cast aluminum Enclosure warning nameplate: silk screened ss
Output I-WPS-
Output II-WPSA-
Output typeSwitch contacts
Output type Switch contacts Contact loading 120 VAC @ 15 AOutput type | Switch contacts | Contact loading | 120 VAC @ 15 A
Pressure requirement5 - 120 psi (With EPV-1 vent. Systems installed without vent must be equipped with redundant regulator set to 5 psi max.)
Safe pressureSetpoint: Class I: 0.25" (6.35 mm); Class II: 1.0" (25.4 mm) Flow rate: 0.1 - 3.5 SCFH (2.8 - 99 l /hr)
Series1001A
SystemType Y Purge , Type Z Purge

器件图片

技术资料