全部替代型号
查看完整报告技术参数
| 电源 | |
|---|---|
| Output type Switch contacts Contact loading 120/220 VAC; 24 VDC @ 10 A; 125 VDC @ 50 mA power requirements: 24 / 120 / 240 VDC @ 3 / 4 / 11 watts | Output type | Switch contacts | Contact loading | 120/220 VAC; 24 VDC @ 10 A; 125 VDC @ 50 mA power requirements: 24 / 120 / 240 VDC @ 3 / 4 / 11 watts |
| Protective gas supply | instrument grade air or inert gas |
| 环境与封装 | |
| Ambient temperature | -29 ... 49 °C (-20.2 ... 120.2 °F) |
| 其他 | |
| Connection | Terminal blocks |
| Connection type | System supply fitting: 1/4" tube fitting Enclosure supply fitting: 1/4" tube fitting Enclosure reference fitting: 1/4" tube fitting Switch conduit port size: 1/2" FPT |
| Contact loading | 120 VAC @ 15 A |
| cULus | Type Y LPS: Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, and G WPS: Class I, Division 1, Groups C, D; Class II, Division 1, Groups E, F, and G WPSA: Class I, Division 1, Groups A, B, C, D Type Z LPS: Class I, Division 2, Groups A, B, C, D; Class II, Division 2, Groups E, F, and G WPS: Class I, Division 2, Groups C, D; Class II, Division 2, Groups E, F, and G WPSA: Class I, Division 2, Groups A, B, C, D |
| FM approval | Type Y LPS: Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, and G WPS: Class I, Division 1, Groups C, D; Class II, Division 1, Groups E, F, and G WPSA: Class I, Division 1, Groups A, B, C, D Type Z LPS: Class I, Division 2, Groups A, B, C, D; Class II, Division 2, Groups E, F, and G WPS: Class I, Division 2, Groups C, D; Class II, Division 2, Groups E, F, and G WPSA: Class I, Division 2, Groups A, B, C, D |
| Hazardous environment | gas or dust |
| Mass | 1001A-LPS-* 2.3 kg (5 lb) 1001A-WPS* 4.5 kg (10 lb) |
| Material | Regulator body: zinc w/enamel finish Regulator handle: polycarbonate Enclosure pressure gauge: alum. w/enamel finish Tube fitting: 316 ss forged body Tubing: 316 ss 1/4" .035 welded System nameplate: silk screened Lexan ® & ss Fastener hardware: alum. & stainless steel Mounting plate: 316 14 ga #3 brush ss EXP pressure switch body: anodized cast aluminum Enclosure warning nameplate: silk screened ss |
| Output I | -WPS- |
| Output II | -WPSA- |
| Output type | Switch contacts |
| Output type Switch contacts Contact loading 120 VAC @ 15 A | Output type | Switch contacts | Contact loading | 120 VAC @ 15 A |
| Pressure requirement | 5 - 120 psi (With EPV-1 vent. Systems installed without vent must be equipped with redundant regulator set to 5 psi max.) |
| Safe pressure | Setpoint: Class I: 0.25" (6.35 mm); Class II: 1.0" (25.4 mm) Flow rate: 0.1 - 3.5 SCFH (2.8 - 99 l /hr) |
| Series | 1001A |
| System | Type Y Purge , Type Z Purge |
器件图片
技术资料