全部替代型号
查看完整报告技术参数
| 电源 | |
|---|---|
| Operating voltage | U B | 10 ... 30 V DC , ripple 10 % SS |
| Power consumption | P 0 | ≤ 900 mW |
| 交流 / 直流特性 | |
| Load impedance | current output: ≤ 500 Ohm voltage output: ≥ 1000 Ohm |
| Repeat accuracy | ≤ 0.1 % of full-scale value |
| Resolution | evaluation range [mm]/4000, but ≥ 0.35 mm |
| Response delay | 65 ms minimum 195 ms factory setting |
| Switch-on delay | t on | < 150 ms |
| Transducer frequency | approx. 180 kHz |
| 环境与封装 | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Temperature influence | ≤ 2 % from full-scale value (with temperature compensation) ≤ 0.2 %/K (without temperature compensation) |
| Temperature/teach-in connector | Temperature compensation , Evaluation range programming , output function setting |
| 其他 | |
| Adjustment range | 120 ... 1500 mm |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Common mode operation | max. 30 Hz |
| Common mode operation max. 30 Hz Multiplex operation ≤ 30/n Hz, n = number of sensors | Common mode operation | max. 30 Hz | Multiplex operation | ≤ 30/n Hz, n = number of sensors |
| Connection type | Connector plug M12 x 1 , 5-pin |
| Dead band | 0 ... 80 mm |
| Degree of protection | IP65 |
| Deviation of the characteristic curve | ≤ 0.2 % of full-scale value |
| Diameter | 30 mm |
| Diameter 30 mm | Diameter | 30 mm |
| Housing | 1.4303 stainless steel plastic parts PBT Sensor well : PTFE |
| Housing 1.4303 stainless steel plastic parts PBT Sensor well : PTFE Transducer PTFE coated; epoxy resin/hollow glass sphere mixture; polyurethane foam | Housing | 1.4303 stainless steel plastic parts PBT Sensor well : PTFE | Transducer | PTFE coated; epoxy resin/hollow glass sphere mixture; polyurethane foam |
| Interface type | RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit |
| LED green | solid: Power-on flashing: Standby mode or program function object detected |
| LED red | solid: temperature/program plug not connected flashing: fault or program function object not detected |
| LED yellow 1 | solid: object in evaluation range flashing: program function |
| LED yellow 2 | solid: object in detection range flashing: program function |
| Mass | 170 g |
| Multiplex operation | ≤ 30/n Hz, n = number of sensors |
| Output type | 1 current output 4 ... 20 mA 1 voltage output 2 ... 10 V |
| Sensing range | 80 ... 1500 mm |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Standards EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 | Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Standard target plate | 100 mm x 100 mm |
| Synchronization | bi-directional 0 level -U B ...+1 V 1 level: +4 V...+U B input impedance: > 12 KOhm synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
| Transducer | PTFE coated; epoxy resin/hollow glass sphere mixture; polyurethane foam |
| UL approval | cULus Listed, General Purpose |
器件图片
技术资料
该型号暂未收录资料。