27689

27689

在产

Advanced diagnostic module, plug-in module for the fieldbus power hub

查看国产替代问 AI FAE

全部替代型号

查看完整报告

技术参数

电源
Fieldbus segment/Supplyfunctional insulation acc. to IEC 62103, rated insulation voltage 50 V eff
Power dissipationmax. 2 W
Rated currentI r | 110 ... 30 mA
Rated voltageU r | 19.2 ... 35 V
环境与封装
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Design / MountingMotherboard based
Height106 mm
Height 106 mm Width 18 mm Depth 128 mmHeight | 106 mm | Width | 18 mm | Depth | 128 mm
Mountingmotherboard mounting
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
其他
CertificateTÜV 04 ATEX 2500 X
Core cross sectionmotherboard specific
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Degree of protectionIEC 60529
Depth128 mm
DIP switchdiagnostic address 1...247, binary coded
Directive 2014/30/EUEN 61326-1:2013
Directive 2014/30/EU EN 61326-1:2013Directive 2014/30/EU | EN 61326-1:2013
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010
Electromagnetic compatibilityNE 21:2011
Fault signalVFC alarm 1 A, 50 V DC, normally closed
Fieldbus segment/Fieldbus segmentfunctional insulation acc. to IEC 62103, rated insulation voltage 50 V eff
Fieldbus typeFOUNDATION Fieldbus/PROFIBUS PA
FM certificateFM 19 US 0015 X and FM 19 CA 0011 X
FM certificate FM 19 US 0015 X and FM 19 CA 0011 X FM marking Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4FM certificate | FM 19 US 0015 X and FM 19 CA 0011 X | FM marking | Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4
FM markingClass I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4
Housing materialPolycarbonate
IECEx certificateIECEx TUN 13.0038X
IECEx certificate IECEx TUN 13.0038X IECEx marking Ex nA IIC T4 GcIECEx certificate | IECEx TUN 13.0038X | IECEx marking | Ex nA IIC T4 Gc
IECEx markingEx nA IIC T4 Gc
Installation in hazardous areaZone 2 / Div. 2
Interface typediagnostic bus: RS 485
LED PRI PWRgreen: on, primary bulk power supply connected
LED SEC PWRgreen: on, secondary bulk power supply connected
LED Seg 1...4yellow: bus activity; red 2 Hz flashing: alarm; red: hardware error
MarkingII 3 G Ex nA IIC T4 Gc
Marking II 3 G Ex nA IIC T4 GcMarking | II 3 G Ex nA IIC T4 Gc
Massapprox. 100 g
Mating cycles100
Number of segments4
PatentsThis product may be covered by the following patent: US7,698,103
Pollution degreemax. 2, according to IEC 60664
Relative humidity< 95 % non-condensing
Shock resistanceEN 60068-2-27
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Vibration resistanceEN 60068-2-6
Width18 mm

器件图片

技术资料

该型号暂未收录资料。